 Measure relative humidity and air temperature, in non-condensing environments, with the HUM1001. This Phidget is useful for environmental controls and weather monitoring. This Phidget connects to your computer through a VINT Hub.

Features:

  • Measure Relative Humidity from 0% to 100%
  • Measure Temperature from -40°C to +85°C
  • Retrieve data as often as every 500 milliseconds
  • Lower noise and higher accuracy than previous Phidgets humidity sensors

-----------------------------------

USER GUIDE

Part 1: Setup

Welcome to the HUM1001 user guide! In order to get started, make sure you have the following hardware on hand:

  • HUM1001 - Humidity Phidget
  • VINT Hub
  • Phidget cable
  • USB cable and computer


Next, you will need to connect the pieces:

HUM1001 Functional.jpeg
  1. Connect the HUM1001 to the VINT Hub using the Phidget cable.
  2. Connect the VINT Hub to your computer with a USB cable.


Now that you have everything together, let's start using the HUM1001!

Phidget Control Panel

In order to demonstrate the functionality of the HUM1001, the Phidget Control Panel running on a Windows machine will be used.


The Phidget Control Panel is available for use on both macOS and Windows machines.

Windows

To open the Phidget Control Panel on Windows, find the Ph.jpg icon in the taskbar. If it is not there, open up the start menu and search for Phidget Control Panel

Windows PhidgetTaskbar.PNG

macOS

To open the Phidget Control Panel on macOS, open Finder and navigate to the Phidget Control Panel in the Applications list. Double click on the Ph.jpg icon to bring up the Phidget Control Panel.


For more information, take a look at the getting started guide for your operating system:


Linux users can follow the getting started with Linux guide and continue reading here for more information about the HUM1001.

First Look

After plugging the HUM1001 into your computer and opening the Phidget Control Panel, you will see something like this:

HUM1001 Panel.jpg


The Phidget Control Panel will list all connected Phidgets and associated objects, as well as the following information:

  • Serial number: allows you to differentiate between similar Phidgets.
  • Channel: allows you to differentiate between similar objects on a Phidget.
  • Version number: corresponds to the firmware version your Phidget is running. If your Phidget is listed in red, your firmware is out of date. Update the firmware by double-clicking the entry.


The Phidget Control Panel can also be used to test your device. Double-clicking on an object will open an example.

Part 2: Using Your Phidget

About

The HUM1001 measures relative humidity from 0% to 100%, and temperature -40°C to +85°C in non-condensing environments.

HUM1001-About.jpg

Explore Your Phidget Channels Using the Control Panel

You can use your Control Panel to explore your Phidget's channels.

1. Open your Control Panel, and you will find the following channels:

HUM1001 Panel.jpg

2. Double click on a channel to open an example program. Each channel belongs to one of these channel classes:

Humidity Sensor: Measures the relative humidity
Temperature Sensor: Measures the ambient temperature

Part 3: Create your Program

1. Setting up your Programming Environment

2. Phidget Programming Basics

-----------------------------------

Product Specifications

Sensor Type:  Humidity / Temperature
Controlled By:  VINT

Humidity Sensor
Humidity Min:  0 %RH
Humidity Max:  100 %RH
Humidity Resolution:  0.01 %RH
Humidity Response Time Max:  10 s
Sampling Interval Min:  500 ms/sample
Sampling Interval Max:  60 s/sample
Humidity Error Max:  ± 2 %RH

Temperature Sensor
Ambient Temperature Min:  -40 °C
Ambient Temperature Max : 85 °C
Temperature Error Typical (At 25°C):  ± 0.2 °C
Temperature Error Max:  ± 1 °C
Temperature Resolution:  0.01 °C
Sampling Interval Max:  60 s/sample
Sampling Interval Min:  500 ms/sample

Electrical Properties
Current Consumption Max:  100 µA

Physical Properties
Operating Temperature Min:  -40 °C
Operating Temperature Max : 85 °C


Shipping weight: 0,05 Kg