The voltage sensor measures the differential voltage between the input terminals and outputs the difference proportionally. The maximum differential voltage that can be accurately measured is ±30V.
Product specifications
Sensor characteristics:
- Sensor type voltage (DC)
- Controlled by voltage input (0-5V)
- Sensor output type not ratiometric
Voltage sensor:
- Voltage difference Max. ± 30 V DC
- Relative input voltage Max. voltage difference ± 40 V DC
- Measurement error Max. 0.5 %.
- Sensor response time max. 10 ms
- Voltage offset Max ± 100 mV DC
- Electrical properties:
- Supply voltage 5 V DC
- Current consumption Max. 3.6 mA
- Sensor input impedance 1 MΩ
- Output voltage Min. 0 V DC DC
- Output voltage Max. 5 V DC
>Physical properties
- Recommended cable cross-section 16 - 26 AWG
- Operating temperature Min -40 °C
- Operating temperature Max. 85 °C
Shipping weight: | 0,02 Kg |
Product weight: | 0,01 Kg |